37
Ground Stud
Power Stud
VEHICLE
BATTERY
SNO-PRO V-PLOW w/SINGLE ACTING CYLINDERS & SPRING RETURN:
RIGHT ANGLE FUNCTION - ELECTRICAL
Ground Connection
Internal in Plow Side Harness
Solenoid Control
Brown Wire
12vdc Switched
By Solenoid
D.)
C.)
E.)
B.)
Chassis Ground
Continuous Connection
A.)
12vdc Source
Black Wire
Must Be Ignition Switched
W1 Extend
V-Plow Touch Pad
BROWN
RED
GREEN
BLUE
WHITE
BLUE/BLACK
WHITE/BLACK
W2 Retract
15a Fuse
What Happens:
A.) Ignition 'On' energizes the Controller Power source sending 12vdc into the Controller. Touch Pad Power Switch must be in the 'On' position.
B.) Pushing the 'Right Angle' button energizes the Blue 'W1 Extend' Wire, White/Black 'W2 Retract' Wire and the Brown 'Solenoid' Wire.
C.) The Brown 'Solenoid' Wire closes the Solenoid Contacts and sends 12vdc power to the Pump Motor.
D.) The Blue 'W1 Extend' Wire sends 12vdc power to the W1 Extend Valve Coil.
E.) The White/Black 'W2 Retract' Wire sends 12vdc power to the W2 Retract Valve Coil. See Next Page for Hydraulic Flow Chart.